Lynx Plus Series Installation and Setup Guide
- 27 -
Data Field Descriptions
48
4848
48
REP
REP REP
REP
FRMT
FRMT FRMT
FRMT PRI
PRI PRI
PRI/S
/S/S
/SEC
ECEC
EC
Report Format for Primary/Secondary
This field is used to select the Primary and Secondary Report Format. (For an
explanation of these formats, see the System Communication section of this manual).
Notes: (1) The maximum number of alarm and alarm restore reports during one armed
period is determined by field 92.
(2) If 3+1 dialer reporting is to be used, Enter
as the 4th digit of 43 through 44.
(3) If Option 5 is selected a 10-digit account number must be entered in Fields 43
or 44.
(4) Option 5 or 7 (ADEMCO Contact ID® Reporting) must be selected for AAV.
SELECTIONS
Primary Secondary
See choices below See choices below
0 = 3+1; 4+1 ADEMCO Low Speed Standard
1 = 3+1; 4+1 Radionics Standard
2 = 4+2 ADEMCO Low Speed Standard
3 = 4+2 Radionics Standard
5 = ADEMCO Contact ID® Reporting with 10-digit subscriber account number
6 = 4+2 ADEMCO Express
7 = ADEMCO Contact ID® Reporting with 4-digit subscriber account number
8 = 3+1; 4+1 ADEMCO Low Speed Expanded
9 = 3+1; 4+1 Radionics Expanded
49
49 49
49
SPLIT/DUAL
SPLIT/DUALSPLIT/DUAL
SPLIT/DUAL
REP
REP REP
REP
Split/Dual Reporting
This field is used to select a reporting option as follows:
Enter: 0 - 5 when reporting to telephone receivers.
6 - 9 when reporting to a pager is desired
10 - 13 when reporting to an aux telephone receiver.
Note: If you are installing a communications module that has voice communications
capability (i.e.; GSMVL), refer to Field
55 notes for additional information.
Pager Report Format
Options 6-9 send reports to the primary phone number, in a format defined in Field
48, and send reports to a pager, which has its phone number entered as the secondary
phone number in Field 42. The pager report is a 7-digit code, with optional 16-digit
prefix. For an explanation of the pager format, refer to the User Guide.
Follow Me System Report Format
Options 10-13 send reports to the primary phone number, in a format defined in Field
48, and sends voice message to the secondary phone number entered in Field 42.
The message is a repeatable system status announcement. If the manual paging option
has been programmed in Field 87, the message will repeat system, system... The
message can be terminated by pressing any key on the telephone keypad.
To Primary To Secondary
0 = All reports None, unless primary fails, then all
1 = Alarms, Restore, Cancel* Others
2 = All except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All
4 = All except Open/Close, Test All
5 = All reports All
To Primary To Paging Number
6= All reports except Open/Close Alarms, Open/Close ‡, Troubles
7= All reports Alarms, Troubles
8= All reports Alarms, Open/Close ‡, Troubles
9= All reports except Open/Close Open/Close ‡,
To Primary To Follow Me System Phone Number
10= All reports except Open/Close Alarms, Open/Close ‡, Troubles
11 = All reports Alarms, Troubles
12= All reports Alarms, Open/Close ‡, Troubles
13= All reports except Open/Close Open/Close ‡
*Recent close report is sent to primary number (LynxSIA Plus only)
Will report Users 0, 5-8, and, if using wireless button-type devices, will report the zone number of the
arm or disarm button 26-33. All other zones and users are not reported.

Table of Contents

Other manuals for Honeywell Lynx Plus Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Lynx Plus Series and is the answer not in the manual?

Honeywell Lynx Plus Series Specifications

General IconGeneral
Wireless Frequency345 MHz
Control Panel TypeSelf-contained
ZonesUp to 40 zones
KeypadIntegrated
CommunicationPOTS, optional GSM, IP
Alarm SounderBuilt-in alarm sounder
Remote ControlYes, via Total Connect 2.0 app
KeyfobsSupports keyfobs
Siren Output95dB built-in siren
CompatibilityCompatible with Honeywell 5800 series wireless devices

Related product manuals