PRO 1000 / 2000 Series
Wiring
A Power supply. Provide disconnect means and overload protection as required.
A Set the O/B jumper according to the type of reversing valve (see page 4).
A Use a piece of wire (not supplied) to connect W and Y terminals to each other.
Optional 24 VAC common connection. If this connection is not made, use batteries
to power the thermostat.
A This connection is not required for systems that provide heating only.
A This connection is not required for systems that provide cooling only.
This connection is not required for systems that do not have an air recirculating fan.
G a s , oil o r e le c tric h e atin g (1 H )
A
Use
TH1100D
G a s , oil o r e le c tric h e atin g an d /o r air c o n d itio n in g ( 1 H / 1 C / 1 H 1 C )
- m
[Ç}
Compressor ] 0
][G}
Fan
Reversing valve] |q/b[
Auxiliary Heat^ |au#e|
Y~
R
C -
A-
- G
- 0/B
- «IKE
Use
TH1210D
or
TH2210D
3
EN G LISH