PRO 1000 / 2000 Series
Installer setup
Follow the procedure below to personalize and
configure the therm ostat according to the heating/
cooling system.
1 Press ^ and simultaneously (for three
seconds) until the display appears as
shown on the right.
2 Press z\ or to change the option.
3 Press /v and for one second to advance
to the next function.
4 When the last function is displayed, press
and to save any changes and exit the
menu.
NOTE: I f y o u d o n o t p re s s a n y b u tto n fo r 6 0 se c o n d s
w h ile y o u a re in the se tu p m enu, th e th e rm o s ta t a u to m a tic a lly s a v e s a n y c h a n g e s m a d e a n d e xits
th e m e n u . F o r p ro g ra m m a b le m o d e ls only, a t a n y tim e y o u ca n s a v e th e c h a n g e s a n d e x it b y
p re s s in g th e Run bu tton.
1
1
n
u
Function
- number
- Option
number
Function1
Default
setting
Options
1 Temperature display format 0
0: Fahrenheit
1: Celsius
2 Time display format 0
0: 12-hour display
1: 24-hour display
3 Heating cycles per hour 5
2 to 6 cycles per hour
2: 30 min (steam, gravity)
3: 20 min (hot water, 90%+ high-efficiency furnace)
4: 15 min (gas or oil)
5: 12 min (gas or oil)
6: 10 min (electric)
4 Cooling cycles per hour 3 2 to 6 cycles per hour
5 Compressor protection2
1
0: Off
1: On
6 Adaptive Intelligent Recovery3
1
0: Off
1: On
7 Application4
0
0: Indoor mode: 40°F to 90°F (4.5°C to 32°C)
1: Garage mode: 35°F to 90°F (1.5°C to 32°C)
1 Depending on your thermostat model or your system type, some functions are non-available or
non-applicable.
2 Damage can occur if the compressor is restarted too soon after shutdown. This feature forces the
compressor to wait 5 minutes before restarting. During the wait time, the message Cool On or Heat On
flashes on the screen. When the safe wait time has elapsed, the message stops flashing and the compressor
turns on.
3 Adaptive Intelligent Recovery allows the thermostat to learn how long your furnace or air conditioner
takes to reach the set temperature. Simply program the desired times and desired temperatures into the
schedule. The thermostat will determine when to activate heating or cooling so that the desired temperature
is attained at the desired time.
4 In Indoor mode, the minimum setpoint is 40°F (5°C) for frost protection. In Garage mode, the minimum
setpoint is 35°F (1.5°C) for energy savings.