Q4000
Installation Instructions
Electromagnetic Water Meters
Water Metering

Other manuals for Honeywell Q4000

Question and Answer IconNeed help?

Do you have a question about the Honeywell Q4000 and is the answer not in the manual?

Honeywell Q4000 Specifications

General IconGeneral
BrandHoneywell
ModelQ4000
CategoryMeasuring Instruments
LanguageEnglish

Summary

Installation Instructions

Electromagnetic Water Meters

Overview of the Q4000 electromagnetic water meter for installation.

Precautions on installation – Meter

Outdoor and Environmental Precautions

Guidance on protecting the meter from sunlight, high temperatures, and downward display mounting.

Installation Clearance and Access

Recommendations for providing adequate space around the meter for piping work and tightening bolts.

Electromagnetic Interference and Stray Current

Advice on avoiding strong electromagnetic fields and stray electrical currents for optimal performance.

Corrosive Environments and Vibration

Instructions to avoid corrosive agents and continuous vibration for meter longevity.

Submergence Depth

Note on observing submergence depth when installing in flooded chambers.

Installation Procedure

Step 1: Initial Bolt Insertion

Insert the studding in the lower two bolts and fix the bolts to the flanges.

Step 2: Meter Placement

Place the electromagnetic meter on the studs and set it in the desired position, avoiding damage.

Step 3: Remaining Bolt Insertion and Alignment

Insert remaining studs, tighten bolts slightly, ensure pipe centre alignment, and fit gaskets.

Step 4: Final Tightening

Tighten nuts diagonally in sequence to fully seal the gaskets.

Precautions on Piping

Pipe Cleaning and Fluid Filling

Ensure pipes are clean and always filled completely with flowing fluid for proper operation.

No Solid Substances

Warning against allowing any solid substances inside the pipe during installation.

Straight Pipe Section Recommendation

Recommendation for installing the meter on a straight section of pipe for accurate measurement.

Air Suction Prevention

Warning to prevent any air from being sucked into the piping system.