EasyManua.ls Logo

Honeywell RTH8500 - Page 23

Honeywell RTH8500
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RTH8500
21
About your new thermostatSystem setup
Manual/Auto changeover
Function
0300
Press s/t to select manual or automatic changeover:
Options: 0 Manual changeover (Heat/Cool/Off).
1 Automatic changeover (Heat/Cool/Auto/Off). Note: System maintains minimum
3°F difference between heat and cool settings.
Temperature format (°F/°C)
Function
0320
Press s/t to set the temperature display format:
Options: 0 Fahrenheit
1 Celsius
Daylight savings time on/off
Function
0330
Press s/t to select an option:
Options: 0 Off: No adjustment for daylight savings time.
1 On: Auto-change to daylight savings time (through 2006, and for areas that
do not use the new 2007 DST calendar).
2 On: Auto-change to daylight savings time (2007 and beyond, for areas that
use the new 2007 DST calendar).
CAUTION: To avoid possible compressor damage, set to option 0 if the outside
temperature drops below 50°F (10°C).

Other manuals for Honeywell RTH8500