EasyManua.ls Logo

Honeywell RTHL2310 series

Honeywell RTHL2310 series
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Thermostat does not work on Heat Pumps with auxiliary/backup heat.
We are here to help. Call 1-800-468-1502 for wiring assistance.
Alternate Wiring
1. If wires will be connected to both R and Rc terminals, remove metal jumper.
2. Do not use C or X. Wrap bare end of wire with electrical tape.
3. If you have a heat pump without auxiliary/backup heat connect O or B, not both. If you do not have a heat
pump, do not connect B. Wrap bare end of wire with electrical tape.
4. Place a jumper (piece of wire) between Y and W if you are using a heat pump without auxiliary/backup heat.
Install Batteries

Other manuals for Honeywell RTHL2310 series

Related product manuals