TH114-AF-GA / TH114-AF-GB
15
ENGLISH
Setpoint range - F mode: 5 °C to 40 °C (40 °F to 104 °F)
- A/AF mode: 5 °C to 30 °C (40 °F to 86 °F)
Floor limit range - AF mode: 5 °C to 40 °C (40 °F - 104 °F)
Display range - F mode: 0 °C to 60 °C (32 °F to 140 °F)
- AF mode: 0 °C to 50 °C (32 °F to 122 °F)
Resolution: 0.5 °C (1 °F)
Heating cycle length: 15 minutes
Data protection: All settings are saved during a power failure.
Technical Specifications
Model Supply
Max. load (resistive only) Ground Fault
Protection
(GFCI)
Wiring
Current Power
TH114-AF-GA
120 VAC, 60 Hz
15 A
1800 W
5 mA
4 wires,
double pole
240 VAC, 60 Hz 3600 W
TH114-AF-GB
120 VAC, 60 Hz 1800 W
15 mA
240 VAC, 60 Hz 3600 W