07/2019 - 4007779101 - 34-VF-25-76 iss.1 GLO July 2019 US 3
Terminal Strand colour
rd red
bu blue
bk black
gr grey
ye yellow
gn green
gnye Shielding
Current output
Current input
Pulse output / frequency output
Limit switch output
Power supply for the signal
converter
Current input (I1+ and I2-) of an external
temperature or pressure transmitter
Connect current loop 4..20 mA to
terminals C1+ and C2-
Connection NAMUR:
M2/4 (common); M3 (open collector)
Connection transistor output:
M2/4 (common); M1 (open collector)
The maximum frequency of both pulse
output and frequency output is 1000 Hz
The connection is made between terminal
M2/4 Common (-) and M1 for Hi Current
(+) or M3 NAMUR (+)
Status output
The connection is made between terminal M2/4 Common (-) and M1 for Hi Current (+) or
M3 NAMUR (+)
Connection of remote version
1 Connection terminal flow sensor
2 Connection terminal signal converter
3 Connection shielding flow sensor
4 Shielding (drain wire and overall shield)
5 Connection shielding signal converter
6 Heat shrink tubing
7 Shielding
1
2
3
4
3
4
5
5
6
6
7 7
Grounding of compact version
1 Ground terminal in housing
2 Ground terminal on connection piece between
flow sensor and signal converter
1
2
Grounding of remote version
1 Ground terminal on flow sensor
2 Ground terminal on signal converter housing
2
1

Other manuals for Honeywell VERSAFLOW VORTEX 200