EasyManua.ls Logo

Honeywell VISTA-15P - System Overview; Introduction; System Basics

Honeywell VISTA-15P
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
88 Program Mode Lockout Options [0]
0 = standard *98 installer code lockout (reentry only by [] + [#] within
50 seconds after power up)
1 = lockout [] + [#] reentry after *98 exit (reenter via installer code or
downloader only)
2 = not used
3 = lockout local programming after *98 exit (reenter by downloader only)
89 Event Log Full Report Code [00] |
See box above field *59 for report code entries.
90 Event Log Enables [3]
NOTE
:
System messages are logged when any non-zero entry is made.
0 = None; 1 = Alarm/Alarm Restore
2 = Trouble/Trouble Restore;
4 = Bypass/Bypass Restore;
8 = Open/Close.
Example:
To select “Alarm/Alarm Restore”, and
“Open/Close”, enter 9 (1 + 8); To select all, enter #15.
91 Option Selection [8, 0]
Options: 0 = None Options V20PSIA/V15PSIA
4 = AAV UL: must use ADEMCO UVCM module Call Wait Disable
8 = Exit Delay Restart/Reset UL: must be disabled
#+12 = AAV and Exit Delay Restart/Reset
SIA Guidelines: Exit Delay should be enabled.
V20PSIA/V15PSIA:
Options: Same as listed above.
Call Waiting Disable:
0 = call waiting not used
1 = call waiting disable digits (*70) entered in field *40; (when
selected, the system dials the entry in field *40 only on
alternate dial attempts; this allows proper dialing in the event
call waiting service is later canceled by the user).
92 Phone Line Monitor Enable [0,0]
UL: see Inst. Instructions for requirements 1 2
NOTE: Output Device must either be programmed to be STOPPED in
field 80 or STOPPED by Code + # + 8 + output number.
Entry 1:: 0 = disabled, 1-15 = 1 min - 15 min
(#+10 = 10 min; #+11 = 11 min; #+12 = 12 min; #+13 = 13 min; #+14
= 14 min; #+15 = 15 min)
Entry 2:
0 = Keypad display when line is faulted
1 = Keypad display plus keypad trouble sound
2 = Same as “1”, plus programmed output device STARTS. If either
partition is armed, external sounder activates also.
93 Reports In Armed Period [1,0]
Per Zone (Swinger Suppression) Restrict V20PSIA/V15PSIA
Restrict Report Pairs: Report Pairs Unlimited
0 = Unlimited Reports Reports Enable
1 = 1 report pair
2 = 2 report pairs SIA Guidelines: Must be set for option 1 or 2.
V20PSIA/V15PSIA:
Restrict Report Pairs: 1 = 1 report pair; 2 = 2 report pairs
Unlimited Reports Enable:
0 = restrict reports to the setting in entry 1
1 = unlimited reports for zones listed in zone list 7; (use zone list 7
to enter those zones that require unlimited reporting; these
zones ignore the setting in entry 1)
DOWNLOAD INFORMATION (
94,
95)
94 Download Phone No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits, 0–9; #+11 for '
'; #+12 for '#'; #+13 for a 2-
second pause. Do not fill unused spaces. If fewer than 20 digits, exit
field by pressing
. To clear entries from field, press
94
.
UL: downloading may be performed only if a technician is at the site.
95 Ring Count For Downloading [15]
NOTE: Do not enter “0” if using 4285/4286 Phone Module.
0 = Disable Station Initiated Download;
1–14 = number of rings (1–9, # +10 =10, # +11 =11,
# +12 =12, # +13 =13, # +14 =14);
15 = answering machine defeat (# +15 =15).
96,
97 Initialize/Reset Defaults
This is a command, not a data field. See page 2.
98, *99 Exit Commands
This is a command, not a data field. See page 2.
PAGER OPTIONS (160- 172)
160 Pager 1 Phone No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. 0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-sec pause
161 Pager 1 Characters
| | | | | | | | | | | | | | |
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
162 Pager 1 Report Options
[0,0,0]
Part. 1 Part. 2 common
For each partition, select from the following options:
0 = no reports sent
1 = Opens/closes all users
4 = All alarms and troubles
5 = All alarms / troubles, and opens/closes for all users
12 = Alarms / troubles for zones entered in zone list 9
13 = Alarms / troubles for zones entered in zone list 9, and
opens/closes for all users
163 Pager 2 Phone No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. 0–9; #+11 = 'Q'; #+12 = '#'; #+13 = 2-sec pause
164 Pager 2 Characters
| | | | | | | | | | | | | | |
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
165 Pager 2 Report Options
[0,0,0]
Part. 1 Part. 2 common
See field *162 for reporting options. Select for each partition (use zone
list 10 if using options 12 or 13).
166 Pager 3 Phone No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. 0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-sec pause
167 Pager 3 Characters
| | | | | | | | | | | | | | |
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
168 Pager 3 Report Options
0,0,0]
Part. 1 Part. 2 common
See field *162 for reporting options. Select for each partition (use zone
list 11 if using options 12 or 13).
169 Pager 4 Phone No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. 0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-sec pause
170 Pager 4 Characters
| | | | | | | | | | | | | | |
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
171 Pager 4 Report Options
[0,0,0]
Part. 1 Part. 2 common
See field *162 for reporting options. Select for each partition (use zone
list 12 if using options 12 or 13).
172 Pager Delay Option For Alarms [3]
0 = none; 1 = 1 minute; 2 = 2 minutes; 3 = 3 minutes
This delay is for ALL pagers in the system.