15
a. Hold DT92E (or its front section, minus mounting plate) approximately 1 metre from ST9420C.
b. Put DT92E into binding mode and reset (clear) any existing binding information as shown.
- Press and hold the button for 2 seconds
- Hold the
and buttons for 3 seconds until display shows ‘Inst’
- Press the
button and the display shows ‘Cont’
- Keep pressing the
button until the display shows ‘CLr’
- Press the
button to clear existing binding data
c. Now put DT92E into binding mode by pressing the
button again. The display will show ‘COnt’.
d. From the ST9420C Guided Binding Menu, select the Room Temperature SENSOR binding mode shown. This will normally have some device
already bound (indicated by ‘bnd’ in the display). Activate binding by pressing the
button.
e. Press the
button on DT92E to send the binding message to ST9420C. If binding was successful DT92E will exit binding mode, and will show
‘Sync’ on its display for up to 4 minutes, as communication and synchronisation are established. The ST9420C display will stop flashing, ‘bnd’
will be shown, and the LoT™ Display will say ‘COMPLETE’ for a few seconds.
f. If binding was unsuccessful, repeat steps a. to e. again. If binding was successful, proceed to step g.
g. Exit Guided Binding Menu by moving the ST9420C slider to the next position and then back again to RUN
h. Now go to section 2.3 to verify communication by using the Signal Strength check.
2 s
3 s
5.5 How to Bind DT92E to ST9420C