DIL switch factory setting
Remove and dispose of component or
packaging
NOTE:
All specified dimensions in the illustrated section are in [mm].
Abbreviations used1.5
Colour code for cables, single conductors and
components
The abbreviations of the colours for identifying the cables,
conductors and components comply with the international
colour code according to IEC 757:
BK Black RD Red
BN Brown WH White
GN Green YE Yellow
Article designations
HE
11-channel receiver
HE
22-channel receiver
HE
33-channel receiver
IT 1 Internal push button with
impulse button
IT 1b Internal push button with
illuminated impulse button
EL 101 One-way photocell
EL 301 One-way photocell
HOR 1 Option relay
HSM 4 4-button mini hand
transmitter
HNA 18 Emergency battery
2 Safety Instructions
ATTENTION:
IMPORTANT SAFETY INSTRUCTIONS.
FOR THE SAFETY OF PERSONS, IT IS IMPORTANT
TO COMPLY WITH THE FOLLOWING INSTRUCTIONS.
THESE INSTRUCTIONS MUST BE KEPT.
2.1 Intended use
The roller garage door operator is designed and intended
exclusively for the operation of smooth-running, spring-
compensated roller garage doors in the domestic, non-
commercial sector. The maximum permissible door size and
maximum weight must not be exceeded.
Note the manufacturer's specifications regarding the door
and operator combination. Potential hazards as outlined in
DIN EN 13241-1 are avoided by construction and fitting
according to our guidelines. Door systems that are located in
a public area and which only have one protective device, such
as a power limit, may only be operated under supervision.
The roller garage door operator is designed for operation in
dry areas.
Non-intended use2.2
Use in the commercial sector is prohibited.
Fitter qualification2.3
Only correct fitting and maintenance in compliance with
the instructions by a competent / specialist company or
a competent / qualified person ensures safe and flawless
operation of the system. According to EN 12635, a specialist
is a person with suitable training, specialist knowledge and
practical experience sufficient to correctly and safely fit, test
and maintain a door system.
Safety instructions for fitting, maintenance, 2.4
repairs and disassembly of the door system
DANGER
Compensating springs are under high tension
See warning in section
▶
3.1
Fitting, maintenance, repairs and disassembly of the door
system and roller garage door must be performed by
a specialist.
In the event of a failure of the roller garage door operator,
▶
a specialist must be commissioned immediately to
perform an inspection or carry out repairs.
Safety instructions for fitting2.5
The specialist carrying out the work must ensure that
installation is conducted in compliance with the prevailing
occupational safety rules and regulations and those governing
the operation of electrical equipment. The relevant national
guidelines must be observed. Potential hazards as outlined in
DIN EN 13241-1 are avoided by construction and fitting
according to our guidelines.
The roller garage door operator is designed for operation in
dry areas.
DANGER
Mains voltage
See the warning in section
▶
3.2 and section 9.1
WARNING
Danger of injury due to damaged components
See warning in section
▶
3.1
Danger of injury due to unexpected door travel
See warning in Section
▶
3.3.5
CAUTION
Danger of crushing in the side guides
See warning in section
▶
3.1
22
TR10A073-B RE / 02.2012
ENGLISH