Problem
Possible
Causes
Remedy
No water
delivery
when gun
trigger is
depressed
(with
supply
hose
connected)
Nozzle
clogged
Clean nozzle
(fig.25)
If the motor starts and does not restart during
operation, wait 2-3 minutes before repeating
the start-up procedure (overload cutout has
been tripped).
If the problem recurs more than once, call
Hozelock Consumer Services on 0121 313 1122.
Technical Data*
Technical Data Unit 7901A
Output L/min 5.2
Maximum Output L/min 8
Pressure MPa 9
Maximum Pressure MPa 13
Power kW 1.7
Tº input (max.) ºC 50
Maximum input pressure MPa 1
Recoil force of the gun at
maximum pressure
N 9.57
Motor Insulation - Class F
Motor Protection - IPX5
Voltage V/Hz
230-
240/50
Sound Level:
**(K = 3dB(A))
L
PA
(EN 60704-1)
L
WA
(EN 60704-1)
dB (A)
dB (A)
80.8
89
Unit Vibrations
***(K = 1.5m/s²) M/s
2
2.81
Net Weight kg 7
Weight (Packed) kg 9
* Subject to technical modifications
** The sound intensity level for the operator may exceed
80.8dB and ear protection measures are necessary.
*** The declared vibration value has been measured in
accordance with a standard test method and may be used
for comparing one tool with another. The declared vibration
value may also be used in a preliminary assessment of
exposure.
WARNING! The vibration emission value during actual use
of the tool can differ from the declared value depending on
the ways in which the tool is used. Identify safety measures
to protect the operator that are based on an estimation of
exposure in the actual conditions of use (taking account of
all parts of the operating cycle such as the times when the
tool is switched off and when it is running idle in addition to
the trigger time).