EasyManua.ls Logo

Hozelock 130 - Troubleshooting Common Issues; Pump Pressure Issues; Pressure Drops During Use

Hozelock 130
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Problem
Possible
Causes
Remedy
Pump does
not reach
working
pressure
Nozzle worn Replace nozzle
Water filter
blocked
Clean filter
(figs.26 & 27)
Water
supply
pressure low
Turn on water
supply tap fully
Air being
sucked into
product
Check tightness of
hose fittings
Air in pump Switch off the
appliance and
keep de-pressing
and releasing the
gun trigger until
the water comes
out in a steady
flow. Switch the
appliance back on
again
Adjustable
nozzle not
positioned
correctly
Turn the adjustable
nozzle (+) (g.14)
Pressure
drops
during use
Water
intake from
external
tank
Connect appliance
to the mains water
supply
Intake water
too hot
Reduce
temperature
Nozzle
clogged
Clean nozzle
(fig.25)
Problem
Possible
Causes
Remedy
Motor
‘sounds’
but fails to
start
Insufficient
power
supply
Check that the
voltage of the
mains power supply
line is the same as
that on the plate
(fig.9)
Voltage loss
due to use
of extension
cable
Check
characteristics of
extension cable
Appliance
not used for
along period
of time
Contact Hozelock
Consumer Services
on 0121 313 1122
Problems
with TSS
device
Contact Hozelock
Consumer Services
on 0121 313 1122
Motor fails
to start
No electrical
power
Check that the
plug is firmly in the
socket and that
the mains voltage
supply is present
Problem
with TSS
device
Contact Hozelock
Consumer Services
on 0121 313 1122
Water
leakage
Seals worn Contact Hozelock
Consumer Services
on 0121 313 1122
Appliance
noisy
Water too
hot
Reduce
temperature
(see technical data)
Oil leakage Seals worn Contact Hozelock
Consumer Services
on 0121 313 1122
Motor
starts even
with gun
trigger is
released
Nozzle
clogged
Clean nozzle
(fig.25)
High
pressure
system
or pump
hydraulic
circuit not
watertight
Contact Hozelock
Consumer Services
on 0121 313 1122

Related product manuals