Sect.
I
Page
2
sensitivity.
The
high
sensitivity
and
de
to
200
kc
bandwidth
which
is
independent
of
sensitivity
make
the
120A
useful
for
medical,
geophysical,
and
industrial
applications.
Phase
shift
measurements
can
be
made
accurately
with
this
oscilloscope
over
a
wide
range
of
input
fre
quencies.
Relative
phase
shift
between
the
vertical
and
horizontal
amplifiers
is
less
than
at
100
kc.
is
an
offset,
round
pin
added
to
a
standard
two-blade
ac
plug
which
grounds
the
instrument
chassis
when
used
with
the
appropriate
receptacle.
To
use
this
plug
in
a
standard
two
contact
outlet
an
adapter
should
be
used
to
connect
the
NEMA
plug
to
the
two
contact
system.
When
the
adapter
is
used
the
ground
connec
tion
becomes
a
short
lead
from
the
adapter
which
can
be
connected
to
the
outlet
mounting
box
for
the
pro
tection
of
operating
personnel.
1-2
DAMAGE
IN
TRANSIT
After
unpacking
this
instrument
should
any
shipping
damage
become
evident,
refer
to
the
Claim
for
Dam
age
in
Shipment
paragraph
on
the
warranty
sheet
in
this
manual.
1-3
POWER
LINE
VOLTAGES
The
Oscilloscope,
like
other
^instruments,
is
shipp
ed
from
the
factory
wired
for
115
volt
ac
line
operation
unless
otherwise
specified
in
the
order.
However,
the
instrument
may
also
be
operated
from
a
230
volt
ac
line
source
if
the
proper
conversion
is
made
to
the
power
transformer.
This
conversion
is
simple,
and
is
described
in
the
Maintenance
section.
1-4
POWER
CORD
The
three
conductor
power
cable
supplied
with
the
in
strument
is
terminated
in
a
polarized
three
prong
male
connector
recommended
by
the
National
Elec
trical
Manufacturer
s
Association.
The
third
contact
CABINET
AND
RACK
MOUNTING
The
Model
120A
Oscilloscope
is
avaihble
as
a
ca
binet
mount
for
bench
or
portable
use
and
as
a
rack
mount
for
installation
in
a
standard
19
inch
equip
ment
rack.
Only
7
inches
of
rack
space
is
required
for
the
120AR
and
it
may
be
supported
in
the
rack
by
the
front
panel
or
on
slides
for
easy
withdrawal
from
the
rack.
Since
both
models
are
electrically
identical
and
differ
pnly
in
mechanical
placement,
this
book
applies
to
both
models.
The
equipment
slides
are
available
only
for
the
rack
mount
model
and
at
extra
cost.
They
can
also
be
in
stalled
at
the
factory
on
special
order
under
Specifi
cation
No.
12001.
1-5
ACCESSORIES
AVAILABLE
An
AC-83A
Viewing
Hood
is
available
at
extra
cost.
This
is
a
face-fitting
moulded
rubber
hood
used
to
shade
the
face
of
the
cathode-ray
tube
under
high
am
bient
light
conditions.
This
will
permit
the
use
of
lower
trace
intensity
setting
which
is
important
es
pecially
with
the
phosphors
susceptable
to
burning,
such
as
the
P7.
Information
concerning
other
cath
ode-ray
tube
phosphors
and
their
corresponding
fil
ters
will
be
found
in
the
following
table.