Adjustments
ADJUSTMENTS
4.
Set
214B
period
to
1000ps
(without
changing the range) and measure
time
between
positive and negative
transition.
Adjust
A2R217
for lOOps.
5.
Set
214B
period
to
10
OOOps
and
release DUTY CYCLE
pushbutton
.
6. Select
.1
m - 1 m
WI
DTH Range, set Width Vernier exactly
to
10
and adjust
A2R216
for
1000ps
width.
7.
Set
Width Vernier
exactly
to
1
and
adjust
A2R
128
for lOOps
width.
8.
Repeat
steps 1
to
7
and
readjust
if
necessary.
9. Check Vernier
Accuracy
for
1-
10
% DUTY CYCLE range
and
.1 m - 1 m
WI
DTH Range.
DUTY CYCLE
RANGE
VERNIER
RESULT
SETTING
1- 10%
1
7511s
-
125ps
Period
10
OOOps
2
160l1s
-
240P5
3
245115
-
355p5
4
330115
-
470ps
5
41511s
-
585p5
6
500l1s
-
700P5
7
58511s
-
815p5
8
670l1s
-
930ps
9
755ps
-
1045ps
10
840l1s
-
1160115
WIDTH RANGE
VERNIER
RESULT
SETTING
.1m - 1m
1
80115
-
120p5
PERIOD
10
OOOps
2
170l1s
-
230ps
3
260115
-
340/15
4
350l1s
-
450ps
5
440115
-
560/15
6
530P5 -
670ps
7
620/1s
-
780P5
8
710115
-
890l1s
9
800ps
-
1000p5
10
890115
-
111Op5
5- 8
Model
214B
Scans by ArtekMedia => 2009