16
(2) The professional repairer is covered by insurance covering liabilities resulting
from its activity, regardless of whether this is required by the Member State.
Repair Process:
When EL capacitors damage or explode, it may lose function and cause product no
work.
The C707, C708 and C709 locations are identified below:
1) You must disconnect the power cord from the power source before
opening the monitor to prevent component damage.
2) Use Multimeter measure whether EL capacitors still have charge. Before
repairing must discharging it.
C605/ C801/ C703/ C708/C707/C709 in following picture need to
discharging.
C707
C709
C703
C707
C709