SECTION
V
CALIBRATION
The
information
contained
in
this
section
is
intended
for
the
use
of
service
trained
personnel
who
understand
electronic
circuitry
and
are
aware
of
the
hazards
invol-
ved.
Do
not
attempt
to
perform
any
of
the
procedures
outlined
in
this
section
unless
you
are
qualified
to
do
so.
5-1.
INTRODUCTION
5-2,
Section
V
contains
Manual
Calibration
Procedures
for
the
HP
3457A
Multimeter.
Section
V
also
con-
tains
information
explaining
the
Calibration
Security
features
built
into
the
3457A.
The
3457A
has
only
two
screwdriver
adjustments
which,
under
normal
conditions,
do
not
require
adjusting.
All
calibration
is
ac-
complished
from
the
front
panel
or
through
computer
control.
5-3.
An
Automatic
Calibration
procedure,
which
includes
software
and
instructions,
is
available
by
ordering
HP
Part
Number
03457-10085
(for
use
with
the
HP
Model
85B)
or
03457-10200
(for
use
with
the
HP
Series
200
computer),
The
equipment
listed
below
is
preferred
for
use
with
the
Automatic
Calibration
Procedure,
however,
other
equipment
may
be
used.
Controller
- - - -
---------------
HP
Model
85B
Computer
or
HP
Series
200
Computer
Frequency
Counter
-
- -
--------+----++--
rrr
rrr
ree
HP
5314A
or
HP
3457A
DC
Voltage/Current
Resistance
Calibrator
Datron
4000A
AC
Voltage/Current/Frequency
Calibrator
-
Datron
4200
5-4.
CALIBRATION
SECURITY
5-5.
The
Calibration
Security
feature
of
the
3457A
allows
the
person
responsible
for
calibration
of
the
unit
to
enter
a
Security
Code
to
prevent
accidental
or
unauthorized
calibration.
5-6.
Security
Code
5-7.
The
Security
Code
is
a
six
digit
integer
number
from
0
through
999,999
(if
the
number
entered
is
not
an
integer
number,
it
will
be
rounded
to
an
integer
value
and
then
used).
The
instrument
is
shipped
from
the
factory
with
the
Security
Code
set
to
3457.
Setting
the
code
to
zero
disables
the
security
feature.
5-8.
Changing
the
Security
Code
(SECURE
<old
security
code>
,
<new
security
code>).
The
procedure
for
changing
the
Security
Code
is
as
follows:
a.
Access
the
SECURE
command.
(Press
the
Blue
SHIFT
key,
then
the
RECALL
/
S
configuration
key.
Use
the
|
scroll
key
to
display
the
SECURE
command).
b.
Enter
the old
Security
Code,
the
delimiter
(
,
)
and
the
new
Security
Code.
(The
instrument
is
shipped
from
the
factory
with
the
security
code
set
to
3457).
Example:
To
change
the
Security
Code
from
3457
to
7543,
enter
3457
,
7543.
c.
Press
the
ENT
key.
The
instrument
will
now
respond
to
the
new
Security
Code.
5-1