EasyManuals Logo

HP 5400R zl2 Series User Manual

HP 5400R zl2 Series
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #85 background imageLoading...
Page #85 background image
5-7
Troubleshooting
Diagnosing with the LEDs
Troubleshooting
The network port
for which the Link
LED is blinking has
experienced a self
test or initialization
failure.
During the module self test, described in tip number 4 earlier in this table, each
network port is also tested. If the port self test fails, the individual port is not usable,
but the rest of the ports on the module, which have passed their self test, will
continue to operate normally.
If the port is a transceiver, verify it is one of the transceivers supported by the
Module. Unsupported transceivers will be identified with this fault condition. The
supported transceivers are listed in the module Installation Guide. The transceivers
are also tested when they are “hot-swapped”--installed or changed after the
Module is installed and receiving power from the switch.
To verify the port has failed, try removing and reinstalling the module, as described
in tip number 4. For the transceivers, you can just remove and reinstall the
transceiver without having to remove the module. If the port fault indication
reoccurs, and you need to be able to use the port, you will have to replace the
transceiver or the module. In the mean time, all the other module ports will operate
normally.
For more information on 40G port self-test or initialization failure, see v3 zl2 module
installation guide.
A fault condition
has been detected
on the power
supply installed in
the slot
corresponding to
the blinking
number.
Try removing and reinstalling the power supply.
Caution: Ensure the AC power cord is disconnected from the supply before removing
and reinstalling the supply.
Reconnect the power supply to the AC power source. If the error indication reoccurs
after the supply is reinstalled, the power supply may be faulty. Call your authorized
reseller or authorized service provider, or use the electronic support services from
HP networking to get assistance. See the Customer Support/Warranty card for more
information.
One or more of the
switch cooling fans
may have failed.
Try disconnecting power from the switch and wait a few moments. Then reconnect
the power to the switch and check the LEDs again. If the error indication reoccurs,
one or more of the fans has failed. The switch has multiple fans and may continue
to operate OK under this condition if the ambient temperature does not exceed
normal room temperature, but for best operation, replace the fan tray. Call your
authorized reseller or authorized service provider, or use the electronic support
services from HP networking to get assistance. See the Customer Support/Warranty
card for more information.
Tip
Number
Problem Solution

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5400R zl2 Series and is the answer not in the manual?

HP 5400R zl2 Series Specifications

General IconGeneral
BrandHP
Model5400R zl2 Series
CategorySwitch
LanguageEnglish

Related product manuals