DEFINE
HEAS
standard
user
defined
+
Width
TT
Mioth
|
[trom
edge
#
Tat
mid
to
Biedge
#
2
at
mid
Define
Measure
Menu
Define
Measurement
Menu
The
upper
threshold
softkey
and
lower
threshold
softkey
allows
you
to
set
the
upper
and
lower
measurement
thresholds.
The
upper
and
lower
thresholds
must
be
set
to
levels
that
fall
on
the
displayed
waveform.
The
message
"not
found"
is
displayed
if
either
threshold
is
not
on
the
waveform.
This
feature
is
used
when
measuring
excessive
overshoot
or
ringing.
By
defining
the
measurements,
you
can
test
for
pass/fail
criteria
of
any
choice.
You
can
test
from
the
front
panel,
or
you
can
set
the
oscilloscope
in
the
limit
test
over
HP-IB
allowing
the
oscilloscope
to
collect
measurement
data
without
supervision.
If
time
measurements
are
performed
and
the
signal
does
not
exceed
8
A/D
levels
or
8
vertical
pixel
levels,
the
message
"not
found"
is
displayed
in
the
measurement
area.
Expand
the
signal
vertically
so
the
oscilloscope
can
make
the
measurement.
Measurements
The
measurements
selection
allows
you
to
further
customize
the
+width,
-width,
and
Atime
(delay)
measurements.
Width
measurements
allow
you
to
select
the
threshold
(upper,
middle,
or
lower).
Where
these
thresholds
occur
is
defined
by
the
thresholds
softkey.
The
Atime
choice
allows
you
to
select
positive
or
negative
slope,
edge
number,
and
threshold
(upper,
middle,
or
lower).
The
oscilloscope
starts
counting
edges
from
the
left
edge
of
the
screen,
not
at
the
reference
point.
The
selected
edge
must
be
displayed.
If
the
edge
is
not
displayed,
the
message
"not
found"
is
displayed
in
the
measurement
results
area
below
the
screen.
You
can
use
Atime
when
measuring
source-to-source
delays
or
measuring
time
separation
on
the
same
source
or
a
different
source.
The
Atime
measurement
is
defined
by
edge
slope,
edge
count
(from
1
to
4000),
and
the
part
of
the
transition
edge
(upper,
lower,
mid)
used
as
a
reference
point.
When
setting
edge
count
fields,
use
the
fine
key.
In
the
coarse
mode
the
oscilloscope
increments/decrements
by
ten
(1,
11,
21,...,4000).
In
the
fine
mode
the
increment/decrement
sequence
is
by
1.
Because
Atime
measurements
are
made
between
two
sources,
the
display
prompts
you
to
select
the
source
(c#,
f#,
m#)
and
the
source
number
for
each
source.
8-9