EasyManuals Logo

HP 6038A Service Manual

HP 6038A
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
Table
3-7.
HP-IB
Commands
(continued)
Command
*Range
or
**Response
to
Query
Description
Paragraph
OUT?
*»OUT
0
or
**OUT
1
Used
to
read
OUTPUT
ON/OFF
setting.
3-144
Tfold
off
Lfold
0
fpOLD
CV
[fold
1
Enables
or
disables
foldback
protection,
which
will
disable
power
supply
output
If
power
supply
switches
to
whichever
mode,
CV
or
CC,
is
defined
as
the
fold
(error)
condition.
Foldback
protection
is
inhibited
during
DELAY
period.
3-145-3-147
'fold
cc
^FOLD
2
Initial
Condition:
FOLD
OFF.
FOLD?
**FOLD
0
or
**FOLD
1
or
**FOLD
2
Used
to
read
FOLDBACK
setting.
3-148
RSI
Used
to
reset
power
supply
if
output
is
disabled
by
overvoltage,
remote
in¬
hibit,
or
foldback
protection
circuits.
Power
supply
resets
to
present
voltage
and
current
settings
(values
can
be
changed
while
unit
is
disabled).
3-149-3-150
f
HOLD
OFF
l^HOLD
0
Thold
on
^HOLD
1
Determine
if
certain
newly
received
commands
are
implemented
by
power
supply
upon
receipt
or
are
held
for
later
implementation
while
power
supply
continues
to
operate
with
previously
received
values.
HOLD
ON
can
be
used
to
synchronize
power
supply
changes
with
actions
taken
by
other
devices
on
the
HP-IB.
See
TRG
command,
initial
Condition:
HOLD
OFF
3-151-3-158
HOLD?
**HOLD
0
or
**HOLD
1
Used
to
read
HOLD
setting.
3-154
fT
TRG
s
Used
to
implement
commands
that
have
been
sent
to
and
held
by
the
power
supply
(power
supply
continues
to
operate
with
previous
values
until
trigger
command
is
received).
See
HOLD
com¬
mand.
The
device
trigger
interface
message
performs
the
same
function.
3-155
STO
X
RCL
X
*0-15
Cause
power
supply
to
store
and
recall
up
to
16
sets
of
the
complete
machine
state
except
for
output
on/off.
Machine
state
consists
of:
programmed
voltage
(first
and
second
rank),
programmed
current
(first
and
second
rank),
soft
voltage
limit,
soft
current
limit,
delay
time,
service
request
on/off,
foldback
(first
and
second
rank),
mask
(first
and
second
rank),
and
hold.
Initial
Condition:
Each
storage
register
is
in¬
itialized
to
the
turn-on
values.
3-159-3-160