3-7.
HP-IB
Commands
(continued)
Command
*Range
or
**Response
to
Query
Description
Paragraph
STS?
**STS
XXX
Used
to
read
the
contents
of
the
status
register,
which
maintains
the
present
status
of
the
power
supply.
See
Table
3-9
for
a
description
of
each
bit
in
the
status
register,
and
the
bit
weight
for
each
condition.
3-161-3-164
ASTS?
**ASTS
XXX
Used
to
read
the
contents
of
the
accumulated-status
register,
which
stores
any
bit
that
was
entered
in
the
status
register
since
the
accumuiated-status
register
was
last
read,
regardless
of
whether
the
condition
still
exists.
The
bit
descriptions
and
weights
are
the
same
as
in
the
status
register,
see
Table
3-9.
3-165-3-167
UNMASK
mnemonics
^UNMASK
XXX
Determines
which
conditions
are
capable
of
setting
bits
in
the
FAULT
register;
therefore,
allows
operator
to
define
which
conditions
are
fault
conditions.
Condi¬
tions
can
be
enabled
either
by
sending
a
string
of
mnemonics
after
the
command
UNMASK,
or
by
sending
the
decimal
equivalent
of
the
total
bit
weight
for
all
con¬
ditions
to
be
enabled.
The
mnemonics
and
bit
weights
are
the
same
as
in
the
status
register,
see
Table
3-9.
Mnemonics
are
separated
from
each
other
by
commas,
and
may
be
sent
in
any
combination
and
in
any
order.
The
command
UNMASK
NONE
disables
all
conditions
from
setting
bits
in
fault
register.
Initial
Condition:
UNMASK
NONE
3-168-3-172
UNMASK?
**UNMASK
XXX
Used
to
read
which
bits
in
the
status
register
have
been
enabled
to
set
bits
in
the
fault
register
(i.e.,which
power
supply
condi¬
tions
are
defined
as
faults),
xxx
is
decoded
using
bit
weights
in
Table
3-9.
3-173
FAULT?
**FAULT
XXX
Used
to
read
which
bits
have
been
set
in
the
fault
register.
A
bit
Is
set
in
the
fault
register
when
the
corresponding
bit
In
the
status
register
changes
from
inactive
to
ac¬
tive
AND
the
corresponding
bit
in
the
mask
register
is
set.
Bits
in
the
fault
register
are
reset
only
after
the
fault
register
is
read,
xxx
is
decoded
using
bit
weights
in
Table
3-9.
3.174-3-175
'SRQ
OFF
SRQO
V.
fSRQ
ON
ISRQ
1
Enable
or
disable
power
supply's
ability
to
request
service
from
the
controller
for
fault
conditions.
UNMASK
command
defines
which
power
supply
conditions
SRQ
are
defined
as
faults.
Initial
Condition:
SRQ
OFF
3-176-3-177