m
Used
to
read
SRQ
setting.
Used
to
initialize
power
supply
to
power-on
state;
also
resets
the
PON
bit
in
the
serial
poll
register.
The
device
clear
in¬
terface
message
performs
the
same
function.
3-180-3-182
ERR?
**ERR
XX
Used
to
determine
type
of
programming
error
detected
by
power
supply,
A
remote
programming
error
will
set
the
ERR
bit
in
the
status
register,
which
can
be
enabled
by
UNMASK
to
request
service.
See
Table
3-10
for
descriptions
of
error
codes.
3-183-3-185
TEST?
**TEST
XX
Causes
power
supply
to
run
self
tests
and
report
any
failures.
Type
of
tests
run
depends
on
whether
power
supply
out¬
put
is
on
or
off.
3-186-3-192
ID?
**HP6038A
or
**HP6038A,
OPT
100
Causes
power
supply
to
report
its
model
number
and
any
options
that
affect
the
unit's
output
capability.
ROM?
**ROM
xxxx
Causes
power
supply
to
report
the
date
code
of
HP-IB
ROM.
{Bracketed
commands
are
equivalent.
X
=
any
digit
(within
range)
MV
=
millivolt
MA
=
milliamp
MS
=
millisecond
**
Query
causes
power
supply
to
clear
output
buffer,
gather
requested
data,
and
store
it
in
output
buffer.
Data
will
be
put
on
HP-IB
when
power
supply
is
addressed
to
talk
and
ATN
goes
false.
Only
most
recently
requested
data
is
stored,
and
it
is
not
saved
after
being
put
on
HP-IB.
3-116
Implicit
separation
occurs
when
the
received
characters
change
from
upper
or
lowercase
alpha
(A...Z,
a...z)
to
numeric
(+,
-
,0..
.9).
Spaces
may
also
be
used
where
im¬
plicit
separation
takes
places.
For
example,
both
the
following
commands
are
correct:
VSET5V
VSET5V
The
question
mark
is
implicitly
separated
from
alpha
characters,
for
example:
VMAX?
VMAX
?
are
both
correct.
3-117
Terminators
for
Data
Sent
to
Power
Supply.
Ter¬
minators
mark
the
end
of
a
command
string,
and
they
instruct
the
power
supply
that
the
command
it
has
just
received
should
be
executed.
The
terminator
characters
are
the
line
feed
and
semicolon.
3-118
Line
feed
is
sent
by
all
HP
controllers
automatically
after
wrt
or
OUTPUT
statements
unless
deliberately
suppressed,
so
the
user
need
not
include
a
terminator
when
only
one
command
is
sent
per
line.
If
the
user
wishes
to
send
more
than
one
command
per
line
the
commands
must
be
separated
by
semicolons.
3-119
Any
number
of
consecutive
terminators
is
treated
as
one.
A
terminator
may
be
preceded
or
followed
by
any
number
of
spaces,
for
example:
VOUT
15V;IOUT
5A
VOUT
15V
;
lOUT
5A
are
both
correct.
3-120
The
carriage
return
character
by
itself
is
not
sufficient
to
terminate
a
command,
but
it
will
be
accepted
without
error
in
all
cases
where
a
terminator
or
separator
is
expected.
3-18