Triggering Measurements
:MODE
The :MODE command is used to set the Trigger Mode for all active
measurements. The trigger mode is defined by two parameters: retriggering and
settling.
Retriggering Syntax
:TRIGger:MODE:RETRigger REPetitive
:TRIGger:MODE:RETRigger SINGle
Retriggering Examples
OUTPUT 714;"TRIG:MODE:RETR REP"
OUTPUT 714;"TRIG:MODE:RETR SING"
Settling Syntax
:TRIGger:MODE:SETTling FAST
:TRIGger:MODE:SETTling FULL
Settling Examples
OUTPUT 714;"TRIG:MODE:SETT FAST"
OUTPUT 714;"TRIG:MODE:SETT FULL"