EasyManua.ls Logo

HP 8920B - Serial Port 9 Configuration

HP 8920B
682 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
422
Chapter 7, IBASIC Controller
Serial I/O from IBASIC Programs
Example IBASIC Program Using Serial Port 10
The following program illustrates I/O to both serial ports. The program sends a
prompt message to a terminal connected to Serial Port 9 and waits for a response
from the user at the terminal. When the response is received from the terminal
connected to Serial Port 9, a series of ASCII characters are sent out Serial Port 10.
10 !....ASCII CHARACTER CYCLER...........
30 !....be connected to a terminal at 9600 baud.
40 !....Outputs ASCII characters on Serial Port 10 beginning with
ASCII
50 !......character 32 (space) and ending with ASCII character 126
(~).
60 !......Characters are output with no CR/LF
70 OUTPUT 9;"When you are ready to send data on port10,press ENTER"
80 OUTPUT 800;"CONF:SPOR:SIN 'IBASIC';BAUD ‘9600'"
90 !Allows IBASIC to read port 9
100 DIM A$[10]
110 ENTER 9;A$ !Program waits here until CR/LF is received.
120 !........
130 I=32
140 HILE I<=126
150 OUTPUT 10 USING "K,#";CHR$(I)
160 !Outputs characters all on one line.
170 OUTPUT 10 USING "K,#";CHR$(I)
180 !Outputs characters all on one line.
190 END WHILE
200 OUTPUT 800;"CONF:SPOR:SIN 'Inst'" !Sets port 9 to IBASIC entry
field.
180 EXECUTE ("CURSOR HOME") !Places cursor at left of IBASIC entry
field
190 END

Table of Contents

Other manuals for HP 8920B