Error 1315 Data from RECC contains invalid bits in word [1,2,3].
Indicates that the decoded data received on the reverse control channel contains invalid
bits in word 1 and/or word 2 and/or word 3. The raw decoded data is displayed in
hexadecimal format in the top right-hand portion of the CALL CONTROL screen. Raw
decoded data is only displayed when the CALL CONTROL screen Display field is set to
Data.
Error 1316 Incomplete data received on RECC for word [1,2,3].
Indicates that the decoded data received on the reverse control channel did not contain the
proper number of bits in word 1 and/or word 2 and/or word 3. The raw decoded data is
displayed in hexadecimal format in the top right-hand portion of the CALL CONTROL
screen. Raw decoded data is only displayed when the CALL CONTROL screen Display
field is set to Data.
Error 1317 Incomplete data received on RVC for word [1,2,3].
Indicates that the decoded data received on the reverse voice channel did not contain the
proper number of bits in word 1 and/or word 2 and/or word 3. The raw decoded data is
displayed in hexadecimal format in the top right-hand portion of the CALL CONTROL
screen. Raw decoded data is only displayed when the CALL CONTROL screen Display
field is set to Data.