4-5
Specifications
Electrical Specifications
Coded Electrical Receiver
Rx Clock and Data
Clock 155.52 MHz with 50% ± 10% duty cycle (typical)
Data Serial stream: 155.52 Mb/s ± 100 ppm
Format CMI
Input Signals STS-3 and STM-1
Equalization Automatic equalization
Monitor Mode 20 dB of fixed gain to cater for nominal monitor point loss
Return Loss > 15 dB (7 MHz to 234 MHz)
Impedance Unbalanced, 75 Ω to ground (nominal)
Protection Maximum applied voltage ± 5 V short term
Connector BNC
Clock 155.52 MHz with 50% ± 10% duty cycle (typical)
Format Non-return to zero (NRZ)
Timing Data set-up time: > 600 ps
Data hold time: > 3.12 ns
Impedance 50 Ω nominal, terminated to −2 V
Level ECL
Interface DC coupled
Connector SMA