Continuable and Non-Continuable Error Codes 103
System Error Codes
• If the System Error continues, 
replace the Interconnect PCA
 ⇒ 
Page 435.
SE Code: 44:11 - Connection problem with the Aerosol Fan
Problem Description:
Aerosol Fan not connected.
Corrective Action:
• Check that the Aerosol Fan cable is not damaged and is correctly connected to the Interconnect 
PCA.
• Replace the Aerosol Fan ⇒ Page 364.
SE Code: 45.01:00 - Rewinder Servo Shutdown
Problem Description:
Problem with the Rewinder servo
Corrective Action:
• Check the spindle is correctly inserted into the Printer.
• Load the substrate again making sure that the media is straight and that a ‘bubble’ is not formed on 
the media path. Do not rewind manual the media when the printer is checking the roll.
• Check that the Spindle is not damaged and the gear at the end the spindle is correctly attached.
• Perform 3.1 Rewinder Motor service test ⇒page 133.
• Check the Rewinder motor cable is not damaged and is correctly connected.
• Replace the Right Roll Housing assembly ⇒ Page 579.
• Replace the Rewinder Motor ⇒ Page 361.
SE Code: 45.02:10 - Rewinder inverse polarity
Problem Description:
Rewinder inverse polarity. This message is only displayed when the printer is initializing
Corrective Action:
• Swap over the power cables of the Rewinder motor.
SE Code: 45.03:00 - Rewinder driver system fault
Problem Description:
There is a system fault with the Rewinder driver.
Corrective Action:
• Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the 
power cord and power On the Printer.
• Check the Rewinder motor cables are not damaged and are correctly connected to the PrintMech 
PCA. 
• Replace the Rewinder Motor ⇒ Page 361.
• Replace the PrintMech PCA ⇒ Page 482.