Service Menu 213
Tests, Utilities & Calibrations
5.3.5 Rewinder C0 Voltage Calibration
Description
This test must be performed whenever the Rewinder Assembly has been replaced or one of the rewinder 
gears have been replaced. The test calculates the optimum power required to move the rewinder system.
Procedure
1. Go to Service Menu >5. Service Calibration Menu>5.3 Substrate Path Menu>5.3.5 Rewinder CO 
Voltage Calib.
2. The front panel displays the following screen, press ok to continue.
The front panel displays the following screen.
When the procedure is finished the following screen is displayed.
5.5 Scan Axis Menu
5.5.1 Scan Axis Calibration
Description
The purpose of this Service Calibration is to carry out a PWM check, calibrate the intensity of the Line 
Sensor and calibrate the Line Sensor position to the Black Printhead.
Perform the Scan Axis Calibration whenever:
• Carriage is disassembled or replaced.
• Encoder Strip is disassembled or replaced.
• Center Platen is disassembled or replaced.
NOTE: Disabling the Heaters ‘1.8.2’ will significantly speed up this procedure.