4. If the calibration process finishes without errors, the new calibration values are checked. If the
values are considered valid, they are displayed and saved for use in future. Press OK to return to
the main screen.
NOTE: Both the Automatic and the Manual Paper Advance Calibration (which can be launched
from the user menu), if they exist, are automatically set to zero for each kind of paper.
5. If the calibration values are not valid, the front panel displays the reason (for example, the
percentage of good navigations is less than 90%). In this case the calibration process has no
effect on the printer. Press OK to return to the main screen.
Reset current calibration
This option sets all the calibration values to zero.
1. The front panel asks for confirmation before proceeding with the reset operation. Press Cancel to
exit or OK to continue with the reset operation.
2. If you press OK, the printer resets the calibration values, after which the following message is
displayed. Press OK to return to the main screen.
Show current calibration values
This option displays the current calibration values. There are ten calibration parameters in total: SLOPE,
AMP1, PH1, FREQ1, AMP2, PH2, FREQ2, AMP3, PH3, and FREQ3. Press OK to return to the main
screen.
126 Chapter 6 Service calibrations ENWW