Drop Detector calibration
The purpose of this Service Calibration is to calibrate the Drop Detector (located in the Service Station)
in relation to the Carriage Assembly. Perform Drop Detector calibration whenever the Drop Detector is
disassembled or replaced.
There are two menu options to calibrate the Drop Detector:
●
Reset Calibration Flag
●
Calibrate Drop Detector
Reset Calibration Flag
Always reset the calibration flag before replacing the Drop Detector, so that the printer will not try to
perform drop detection until the new Drop Detector has been calibrated.
1. In the Service Calibrations submenu, select Drop Detector calibration and press OK.
2. In the Drop Detector Calibration menu, select Reset Calibration Flag and press OK.
3. When the following message appears on the front panel, press OK to continue with the
calibration; press Cancel to exit.
ENWW
Entering the Service Calibrations menu