Entering the Service Calibrations Menu 167
Service Calibrations
Perform the Vacuum Calibration as follows:
1. In the Service Calibrations submenu, scroll to “Vacuum Calibration” and press Enter.
2. When the following message appears on the front panel, you must select whether you would like to
continue with the calibration by pressing the Enter key. Press Back or Cancel to exit the
calibration.
3. The Printer will set the default nominal and real values of the Vacuum Fan.
4. Once the calibration is completed, OK will be displayed on the Front Panel.
6. OMAS Calibration
The purpose of this Service Calibration is to calibrate the OMAS Module. The calibration process consists
of printing a special calibration plot and then scanning it with the printer.The scanned result values are
compared with the actual printed values to obtain a PASS/FAIL result.
Perform the OMAS Module Calibration as follows:
In the Service Calibrations submenu, scroll to “OMAS Calibration” and press Enter.
NOTE: In order to perform this Calibration, you should order the Paper Advance Calibration
Kit (Part Number Q1273-60296) which contains two cut sheets of HP Universal Instant-dry
Gloss Photo media (36-inches wide by 42-inches long).