Basic installations 8
Basic installations
This chapter covers basic ProLiant deployments using the Solaris media. For more information on
other types of deployments, see “Using this guide.”
Prerequisites
To perform a basic installation of Sun Solaris on HP ProLiant servers, the following prerequisites must
be met:
HP ProLiant ServerUse the ProLiant server support matrix for Solaris to determine which
releases of Solaris 10 are supported on your ProLiant.
Sun Solaris 10 Distribution MediaObtain a copy of the appropriate release of Solaris 10 from
Sun Microsystems. Both CD and DVD media are supported.
Additional DriversDepending on your ProLiant model, one or more of the following additional
drivers that are not found on the Solaris media might be required. These drivers are available
from http://www.hp.com
on the “Software and Drivers” page associated with each ProLiant
model.
HP Smart Array controller driverIf you are installing to disks attached to a Smart Array
controller, the Smart Array driver cpqary3 is required during installation. For information
about additional requirements, including the use of a Driver Update diskette or CD, see the
HP Smart Array Controller Driver for Solaris 10 User Guide at
ftp://ftp.compaq.com/pub/softlib2/software1/pubsw-windows/p308167783/v40878/
HP_Smart_Array_Controller_Driver_User_Guide.pdf. The Smart Array driver is listed as “HP
Driver Update (DU) for Solaris (x86) 10” on the “Software and Drivers” page.
Broadcom NetXtreme II driverIf you are using network interface card (NIC) models
NC370x, NC371x, NC373x, NC374x, or NC380x, the bnx driver is required. This driver
is applied post-installation.
CD or DVD driveA CD-ROM or DVD-ROM drive is required to load the Solaris software. A
Universal Serial Bus (USB) drive or iLO virtual media can be used if an internal drive is not
available.
HP SmartStart CDFor advanced Smart Array configuration, HP SmartStart is required to set up
the arrays. For basic array setup, the Option ROM Configuration for Arrays (ORCA) utility can
be used instead.
Firmware updatesHP recommends using the latest system ROM and firmware. System ROM,
Smart Array controller firmware, and iLO firmware updates should be applied when available.
iLO clientIf using iLO to perform the installation, a supported iLO client is required.
iLO Advanced licenseIf using iLO to perform the installation, an iLO Advanced license is
required. This license is included with all blades.
The most efficient method to deploy Solaris on ProLiant server blades is through the network. If
network deployment is not available, a USB CD/DVD drive can be connected to the blade or iLO
virtual media can be used.
You can install Sun Solaris software using only virtual media, but it is not recommended. For best
results, verify that the iLO firmware is up-to-date. Connecting media images over HTTP using the iLO
secure shell interface can yield improved performance over the Java applet browser interface.

Table of Contents

Other manuals for HP Dl180 - G6 E5504 2X2gb 4Lff Svr

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Dl180 - G6 E5504 2X2gb 4Lff Svr and is the answer not in the manual?

HP Dl180 - G6 E5504 2X2gb 4Lff Svr Specifications

General IconGeneral
ModelHP ProLiant DL180 G6
ProcessorIntel Xeon E5504
Processor Speed2.0 GHz
Processor Count1
Memory4 GB (2 x 2 GB)
Memory TypeDDR3
Drive SupportSATA/SAS
Network2 x Gigabit Ethernet
Form Factor2U rackmount
Memory Slots12
Maximum Memory96 GB
Drive Bays4 LFF
RAID SupportHP Smart Array P410
Expansion Slots2 x PCI-Express
Power Supply460W
Operating System SupportWindows Server, Red Hat, SUSE, VMware