Removal and replacement procedures 65
Figure 57 Installing the system board
Power supply unit (PSU)
Located on the rear panel of the server power supply is a standard autoranging 750-watt PSU with
PFC (power factor correction) function.
Figure 58 Power supply unit
WARNING: Take note of the following reminders to reduce the risk of personal injury from electric
shock hazards and/or damage to the equipment.
•
Installation of power supply units should be referred to individuals who are qualified to service server
systems and are trained to deal with equipment capable of generating hazardous energy levels.
• DO NOT open the power supply unit. There are no serviceable parts inside it.
To remove the power supply:
1. Press the blue colored handle.
2. Slide the power supply out of the power supply bay.