[:SOURce]:PHASe
The :PHASe command subsystem allows control
of
the phase of the
output signal against a reference.
Subsystem Syntax
[:SOURce]
:PHASe
[:AD Just] <numeric value>
:STEP <numeric value>
:REFerence <event
>
:UNIT RADian
I
DEGree
Comments
:PHAse[:ADJust]
Controls the phase offset value relative to the
reference. The command allows steps by substituting UP or
DOWN for the parameter.
:PHASe[:ADJust]:STEP
Controls the step size in radians.
A
DEGree or RADian suffix can be applied.
:PHASe:REFerence
Is an event which allocates the current phase
to be the reference for future phase adjustments. This function is
non-query able.
rn
:PHASe:UNIT
This command specifies the default unit (radian
or degree). When querying a value without adding :UNIT?, only
a numeric value will be returned. It is always advisable to use
:UNIT?
Example:
:PHASe?;:PHAS:UNIT? <CR (return)>
may provide a response "24.3;DEGU
Command
Reference
5-23