4. If it is necessary to replace the webcamera/microphone module:
The webcam is available using spare part number 762521-001 for non-touch models and 767545-001
for touch models.
a. Disconnect the webcamera/microphone module cable (1) from the webcamera/microphone
module. (The webcamera/microphone module cable is part of the display panel cable.)
b. Detach the webcamera/microphone module (2) from the display back cover.
5. If it is necessary to replace the hinges:
The hinges are available using spare part number 767248-001 for non-touch models.
a. Remove the two top screws (1) from the display hinges.
b. Remove the four bottom screws (2) from the display hinges.
70 Chapter 6 Removal and replacement procedures for Authorized Service Provider parts