This example shows how to display diagnostic test results for a specific Fabric Extender unit:
switch(config-fex)# show diagnostic result fex 100
FEX-100: Fabric Extender 16x10GE + 8x10G Module SerialNo : FOC1514256S
Overall Diagnostic Result for FEX-100 : OK
Test results: (. = Pass, F = Fail, U = Untested)
TestPlatform:
0) SPROM: ---------------> .
1) Inband interface: ---------------> .
2) Fan: ---------------> .
3) Power Supply: ---------------> .
4) Temperature Sensor: ---------------> .
Eth 1 2 3 4 5 6 7 8
Port -------------------------
. . . . . . . .
Eth 9 10 11 12 13 14 15 16
Port ------------------------
. . . . . . . .
TestFabricPorts:
Fabric 1 2 3 4 5 6 7 8
Port -------------------------
. . . . . . . .
switch(config-fex)#
This example shows how to display the environment status for a specific Fabric Extender unit:
switch(config-fex)# show environment fex 100
Temperature Fex 100:
-----------------------------------------------------------------
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
-----------------------------------------------------------------
1 Outlet-1 85 75 39 ok
1 Outlet-2 85 75 48 ok
1 Inlet-1 85 75 36 ok
1 Inlet-2 85 75 27 ok
1 Die-1 110 105 55 ok
switch(config-fex)#
This example shows how to display the SPROM for a specific Fabric Extender unit:
switch(config-fex)# show sprom fex 100 all
DISPLAY FEX 100 SUP sprom contents
Common block:
Block Signature : 0xabab
Block Version : 3
Block Length : 160
Block Checksum : 0x1860
EEPROM Size : 65535
Block Count : 3
FRU Major Type : 0x6002
FRU Minor Type : 0x0
OEM String : Cisco Systems, Inc.
Product Number : N2K-B22HP-P
Serial Number : FOC1514256S
Part Number : 73-13780-05
Part Revision : 02
Mfg Deviation : 0
H/W Version : 0.501
Mfg Bits : 0
Engineer Use : 0