Removal and Replacement
Bottom Assemblies
Note
When removing the DC Controller Assembly
there will be resistance where the connectors are
attached (on the left in Figure 6-36). A firm tug
may be necessary to free the assembly.
Figure 6-36 Removing the DC Controller Assembly
To re-instalh
When reinstalling the DC Controller, be sure to use a short length
(6 mm) machine screw at Figure 6-36, callout 3. A longer (10 mm)
screw will obstruct the Fusing Assembly.
Ensure that the PSI Input Paper Sensor Arm (Figure 6-51), and
the PS2 Paper-out Sensor Flagon the D-Roller Assembly (Figure
6-41, callout 2) are in their proper positions. The Input Paper
Sensor Arm should operate freely. If either of these are not seated
properly, this will cause a continuous Paper Jam error condition.
6-40