Scanner/ADF assembly
1. Remove the left cover. See Left cover on page 102.
2. Disconnect two FFC connectors (callout 1; J4 and J27), and two wire-harness connectors (callout 2;
J2 and J36) from the formatter. Disconnect one ground-wire terminal lug (callout 3) from the product
chassis.
CAUTION: Do not bend or fold the flat flexible cables (FFCs) during removal or installation. Also,
do not straighten pre-folds in the FFCs. You must make sure that all FFCs are fully seated in their
connectors. Failure to fully seat an FFC into a connector can cause a short circuit in a PCA.
Figure 5-34 Remove the scanner/ADF assembly (1 of 4)
2
1
3
3. Remove one screw (callout 4) to remove the ferrite from the chassis (callout 5), and then feed the
cables out through the ferrite.
Figure 5-35 Remove the scanner/ADF assembly (2 of 4)
4
5
ENWW Scanner/ADF assembly 117