5. Release seven tabs (callout 1) and remove the high-voltage power supply assembly (callout 2).
Figure 1-68 Remove the high-voltage power supply (4 of 4)
1
1 2
Reinstall the power supply (high voltage)
●
Make sure that the power supply is correctly positioned under the tabs (callout 1) located on the
product chassis. If the power supply is not correctly installed, the product will not function correctly
and a fuser open error (50.7000) might appear in the event log.
Figure 1-69 Reinstall the power supply (high voltage)
1
1 2
58 Chapter 1 Removal and replacement ENWW