Pickup/feed operation
The HCI operation picks up paper in the cassette one sheet at a time and feeds it to the device. This
section describes the pickup/feed operation for the 1 x 500-sheet HCI and the top cassette of the 3 x 500-
sheet HCI. The pickup/feed operation for the center and bottom cassettes of the 3 x 500-sheet HCI is
the same as the top cassette.
HCI driver PCA
HCI PAPER LENGTH DETECTION signal
HCI PAPER WIDTH DETECTION signal
HCI LIFTER MOTOR DRIVE signal
HCI PICK-UP MOTOR DRIVE signal
HCI FEED DETECTION signal (P_TOP)
HCI CASSETTE PAPER signal (P_SNS)
HCI PAPER STACK SRUFACE signal (P_LVL)
HCI PICK-UP SOLENOID DRIVE signal (PICKDV)
HCI pick-up roller
HCI feed roller
HCI paper separation roller
Figure 4-33 HCI paper pickup/feed operation
●
The DC controller operates the HCI driver PCA when it receives a print command from the
formatter.
●
The HCI driver PCA performs the pickup/feed operation for the HCI. The PCA picks up the paper
and feeds it to the device entrance.
The following table lists the assigned electrical component codes for the 1 x 500-sheet HCI cassette
and the 3 x 500-sheet HCI cassettes.
Table 4-5 HCI paper pickup/feed operation
Component name 1 x 500-sheet HCI cassette
3 x 500-sheet HCI top
cassette
3 x 500-sheet HCI middle
cassette
3 x 500-sheet HCI bottom
cassette
HCI cassette paper sensor SR2 SR6 SR8
HCI stack surface sensor SR1 SR5 SR7
140 Chapter 4 Theory of operation ENWW