Transmission assemblies and slide rail
1. Remove the following components or assemblies:
●
ADF. See
ADF assembly on page 204.
●
Scanner. See
Scanner assembly on page 232.
●
Scanner glass assembly and top cover. See
Glass assembly and top cover on page 235.
●
Scanner optic assembly. See
Optic assembly on page 240.
2. Disconnect one connector (callout 1) and pass the transmission motor wire harness through the
wire retainer (callout 2). Carefully pass the wire harness through the opening (behind the PCA) in
the scanner chassis into the scanner bed.
Tip It might be easier to pass the wire harness into the scanner bed if you remove the
scanner PCA.
Figure 5-115 Remove the scanner transmission assemblies and slide rail (1 of 5)
250 Chapter 5 Removal and replacement ENWW