Table 3-36 Jetdirect Menu (continued)
First level Second level Third level Fourth level Values Description
Diagnostics Embedded Tests LAN HW Test Yes
No*
Provides tests to help
diagnose network
hardware or TCP/IP
network connection
problems.
Embedded tests help
to identify whether a
network fault is
internal or external to
the product. Use an
embedded test to
check hardware and
communication paths
on the print server.
After you select and
enable a test and set
the execution time,
you must select the
Execute option to
initiate the test.
Depending on the
execution time, a
selected test runs
continuously until
either the product is
turned off or an error
occurs and a
diagnostic page is
printed.
CAUTION: Running
this embedded test
will erase your TCP/IP
configuration.
This test performs an
internal loopback test.
An internal loopback
test will send and
receive packets only
on the internal
network hardware.
There are no external
transmissions on your
network.
HTTP Test Yes
No*
Checks operation of
HTTP by retrieving
predefined pages
from the product, and
tests the HP
Embedded Web
Server.
Select the Yes option
to use this test, or the
No option to not use
it.
ENWW Tools for troubleshooting 377