EasyManuals Logo

HP ProCurve 5406zl User Manual

HP ProCurve 5406zl
460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #281 background imageLoading...
Page #281 background image
5-63
Quality of Service: Managing Bandwidth More Effectively
Globally-Configured QoS
Example. This example shows how to prioritize inbound traffic on the
following source-ports:
Enter the following commands to prioritize packets received from the speci-
fied source ports:
Figure 5-28. Configuring and Displaying Source-Port QoS Priorities
If you later decided to remove source-port A1 from QoS prioritization, you
would enter the following command:
Syntax: no interface < port-list > qos
Disables use of the specified source-port(s) for QoS classi-
fier(s) and resets the priority for the specified source-port(s)
to No-override.
Syntax: show qos port-priority
Lists the QoS port-priority classifiers with their priority
data.
Source-Port Priority
A1 - A3 2
A4 3
B1, B4 5
C1-C3 6
HP Switch(config)# interface 1-3 qos priority 6
HP Switch(config)# interface 4-5 qos priority 5
HP Switch(config)# interface 6-7 qos priority 3
Switch(config)# show qos port-priority
Port priorities
Port Apply rule | DSCP Priority Radius Override
---- ----------- + ------ ----------- ---------------
1 Priority | 6 No-override
2 Priority | 6 No-override
3 Priority | 6 No-override
4 Priority | 5 No-override
5 Priority | 5 No-override
6 Priority | 3 No-override
7 Priority | 3 No-override
8 No-override | No-override No-override
9 No-override | No-override No-override
10 No-override | No-override No-override

Table of Contents

Other manuals for HP ProCurve 5406zl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 5406zl and is the answer not in the manual?

HP ProCurve 5406zl Specifications

General IconGeneral
Product NameHP ProCurve 5406zl
CategorySwitch
LayerLayer 3
Operating Temperature32°F to 131°F (0°C to 55°C)
Operating Humidity15% to 95% non-condensing
ManagementSNMP, CLI
Power SupplyRedundant power supplies (optional)
Memory128 MB flash, 512 MB SDRAM

Related product manuals