2-7
GVRP
Per-Port Options for Handling GVRP “Unknown VLANs”
Table 2-1. Options for Handling “Unknown VLAN” Advertisements:
The CLI show gvrp command and the menu interface VLAN Support screen
show a switch’s current GVRP configuration, including the Unknown VLAN
settings.
Figure 2-3. Example of GVRP Unknown VLAN Settings
Unknown VLAN
Mode
Operation
Learn
(the Default)
Enables the port to become a member of any unknown VLAN for which it
receives an advertisement. Allows the port to advertise other VLANs that
have at least one other port on the same switch as a member.
Block Prevents the port from joining any new dynamic VLANs for which it receives
an advertisement.
Allows the port to advertise other VLANs that have at least one other port
as a member.
Disable Causes the port to ignore and drop all GVRP advertisements it receives and
also prevents the port from sending any GVRP advertisements.
HP Switch(config)# show gvrp
GVRP support
Maximum VLANs to support [256] : 256
Primary VLAN : DEFAULT_VLAN
GVRP Enabled [No] : Yes
Port Type | Unknown VLAN Join Leave Leaveall
---- --------- + ------------ ----- ----- --------
1 10/100TX | Learn 20 300 1000
2 10/100TX | Learn 20 300 1000
3 10/100TX | Learn 20 300 1000
4 10/100TX | Learn 20 300 1000
5 10/100TX | Learn 20 300 1000
6 10/100TX | Learn 20 300 1000
. . . . . .
GVRP Enabled
(Required for Unknown
VLAN operation.)
Unknown
VLAN
Settings
Default:
Learn

Table of Contents

Other manuals for HP ProCurve 5406zl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 5406zl and is the answer not in the manual?

HP ProCurve 5406zl Specifications

General IconGeneral
Product NameHP ProCurve 5406zl
CategorySwitch
LayerLayer 3
Operating Temperature32°F to 131°F (0°C to 55°C)
Operating Humidity15% to 95% non-condensing
ManagementSNMP, CLI
Power SupplyRedundant power supplies (optional)
Memory128 MB flash, 512 MB SDRAM