ProCurve Switch vl Modules
Mode Conditioning Patch Cord for Gigabit-LX
Installing the Patch Cord
As shown in the illustration below, connect the patch cord to the Gigabit-LX 
mini-GBIC with the section of single-mode fiber plugged in to the Tx (transmit) 
port. Then, connect the other end of the patch cord to your network cabling 
patch panel, or directly to the network multimode fiber.
If you connect the patch cord directly to the network cabling, you may need 
to install a female-to-female adapter to allow the cables to be connected 
together.
Figure 14. Mode Conditioning Patch Cord
Ensure you purchase a patch cord that has LC connectors on the end that 
connects to the Gigabit-LX mini-GBIC, and has multimode fibers that match 
the characteristics of the multimode fiber in your network.
to network 
multimode 
cabling
the multimode cable in the patch cord 
must match the characteristics of your 
network cable
Gigabit-LX port
single-mode section plugs into Tx 
port on Gigabit-LX mini-GBIC
LC Connector