Diagnostic tools and setup utilities 148
POST error indicators
When POST detects a system failure, it displays a POST error message.
POST error descriptions
When a non-fatal error occurs during POST, the screen will display an error message with the format
“xxx-Error Identifier String” where “xxx” is a unique number code that matches ODM system specific
error documentation and may be a hexadecimal or decimal value.
All Error messages describe the problems as shown below:
Table 28
POST Error Messages
Error code
Description
10 Floppy Controller Failure
00B CMOS Memory Size Wrong
00C
RAM R/W test failed
003 CMOS Battery Low
005 CMOS Checksum Bad
040 Refresh timer test failed
041 Display memory test failed
048 Password check failed
120 $A0CCMOS Cleared by Jumper. Restore the Jumper and Continue…
122 $A0CPassword Cleared By Jumper. Restore the Jumper and Continue…
150 Processor failed BIST
160 Processor missing microcode:
192 L3 cache size mismatch
193 CPUID, Processor stepping are different
194 CPUID, Processor family are different
195 Front side bus mismatch. System halted.
196 CPUID, Processor Model are different
197 Processor speeds mismatched
198 Processor QPI speed mismatch detected.
601 Error: BMC Not Responding
605 BMC Has Detected Fatal Hardware Error
611 Internal User Area Of BMC FRU Corrupted
612 Controller Update 'boot block' Firmware Corrupted
613 Controller Operational Firmware Corrupted