Diagnostics and Troubleshooting
4-40 Compaq ProLiant DL360 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM
Table 4-16: ADU Diagnostic Messages
Message Description Recommended Action
Accelerator
board not
detected
Array controller did not detect a
configured array accelerator board.
Install the array accelerator board on the
array controller. If an array accelerator
board is already installed, check for proper
seating on the array controller board.
Accelerator
error log
List of the last 32 parity errors on
transfers to or from memory on the
array accelerator board; displays
starting memory address, transfer
count, and operation (read and
write).
If there are many parity errors, you may
need to replace the array accelerator
board.
Accelerator
parity read
errors: n
Number of times that read memory
parity errors were detected during
transfers from memory on array
accelerator board.
If there are many parity errors, you may
need to replace the array accelerator
board.
Accelerator
parity write
errors: n
Number of times that write memory
parity errors were detected during
transfers to memory on the array
accelerator board.
If there are many parity errors, you may
need to replace the array accelerator
board.
Accelerator
status: Cache
was
automatically
configured
during last
controller
reset.
This can occur when cache board
is replaced with one of a different
size.
Normal operations should continue.
Accelerator
status: Data in
the cache was
lost due to
some reason
other than the
battery being
discharged
Data in the cache was lost, but not
because of the battery being
discharged.
Ensure that the array accelerator is
properly seated. If the error continues, you
may need to replace the array accelerator.
Accelerator
status: Dirty
data detected
has reached
limit. Cache
still enabled,
but writes no
longer being
posted
The number of cache lines
containing dirty data that cannot be
flushed (written) to the drives has
reached a preset limit. The cache is
still enabled, but writes are no
longer being posted. This error
usually occurs when there is a
problem with the drive(s).
Resolve problem with drive(s). The
controller will then be able to write dirty
data to drives and posted write operations
will be restored.
Accelerator
status: Dirty
data detected.
Unable to
write dirty
data to drives
At least one cache line contains
dirty data that the controller has
been unable to flush (write) to the
drives. This problem usually occurs
when there is a problem with the
drive(s).
Resolve the problem with the drive(s). The
controller will then be able to write dirty
data to drives.
continued