Diagnostics and Troubleshooting 
Compaq ProLiant DL360 Server Maintenance and Service Guide  4-49 
 
 
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM 
 
Table 4-16:  ADU Diagnostic Messages continued 
Message Description Recommended Action 
Unable to 
communicate 
with drive on 
SCSI Port x, 
Drive ID x 
Controller could not communicate 
with drive. 
If the amber LED on the drive is on, 
replace the drive. 
Unknown 
disable code 
A code was returned from the array 
accelerator board that ADU does 
not recognize. 
Obtain the latest version of ADU. 
Unrecoverabl
e read error 
Read parity errors were detected 
when attempting to read same data 
from both sides of mirrored 
memory. Data loss will occur. 
Replace the array accelerator board. 
WARNING - 
Drive Write 
Cache is 
enabled on X 
Drive has its internal write cache 
enabled. The drive may be a 
third-party drive, or the operating 
parameters of the drive may have 
been altered. This condition may 
cause data corruption if power to 
the drive is interrupted. 
Replace the drive with a drive supplied by 
Compaq, or restore the operating 
parameters of the drive. 
Warning bit 
detected 
A monitor and performance 
threshold violation may have 
occurred. Status of a logical drive 
may not be OK. 
Check the other error messages on the 
diagnosis screen for an indication of the 
problem. 
Write memory 
error 
Data could not be written to cache 
memory. This typically means that 
parity error was detected while 
writing data to cache. This could be 
caused by incomplete connection 
between cache and controller. This 
is not a data loss circumstance. 
With power to system turned off, verify 
that the cache board is fully connected to 
controller. 
Wrong 
Accelerator 
This could mean that either the 
board was replaced in the wrong 
slot or placed in a system that was 
previously configured with another 
board type. Included with this 
message is a message indicating 
the type of adapter sensed by ADU 
and a message indicating the type 
of adapter last configured in 
nonvolatile RAM. 
Check the diagnosis screen for other error 
messages. Run the System Configuration 
Utility to update the system configuration.