Removal and Replacement Procedures 
Compaq ProLiant DL360 Server Maintenance and Service Guide  2-27 
 
 
COMPAQ CONFIDENTIAL Codename: MicroMachine Part Number: 169616-006 Last Saved On: 12/31/01 11:05 AM 
 
Fan Assembly 
To remove the fan assembly:  
1.  Complete the preparation procedures. See “Powering Down the Server” earlier in this 
chapter. 
2.  Remove the access panel. See “Server Access Panel” earlier in this chapter. 
3.  Remove the PCI riser board assembly. See “PCI Riser Board Assembly” earlier in this 
chapter. 
4.  Remove the air baffle. See “Air Baffle” earlier in this chapter. 
5.  Press the retaining clips on both sides of the fan assembly 
. 
6.  Lift the fan assembly vertically and remove it from the chassis 
. 
2
1
1
 
Figure 2-22:  Removing the fan assembly 
Reverse steps 1 through 6 to replace the fan assembly, ensuring that the fan locks into place.