Diagnostics and Troubleshooting
4-22 Compaq ProLiant DL360 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM
Table 4-2: POST Error Messages continued
Error Code Audible Beeps
Probable Source of
Problem Recommended Action
1785-Drive Array
not Configured
(followed by one
of the following)
Run Compaq
Array
Configuration
Utility
No drives
detected.
Drive positions
appear to have
changed.
Drive positions
appear to have
changed.
Configuration
information
indicates drive
positions beyond
the capability of
this controller.
This may be due
to drive
movement from a
controller that
supports more
drives than the
current controller.
None Configuration error See actions below.
Run the Compaq Array
Configuration Utility.
Turn off the system and check
the SCSI cable connections to
make sure the drives are
attached properly.
Run Array Diagnostic Utility if
previous positions are
unknown. Then turn system
power Off and move drives to
their original positions.
To avoid data loss turn system
power Off and reattach drives
to the original controller
firmware to the version on the
original controller using Option
ROMPaq. Press the F1 key to
resume.
continued